PRODUCT
LPG
PRESSURE REGULATOR I
FLOW METER II
GAS METER
Diaphragm Gas Meter
G10, G16, G25
SPECIFICATIONS
G10 | G16 | G25 | |
---|---|---|---|
Nominal Diameter (DN) | 40mm | 50mm | |
Operating Pressure (Bar) | 0.5 (1 bar option) | ||
Cyclic Volume (dm³) | 6 | 12 | |
Minimum capacity (m³/h) | 0.1 | 0.16 | 0.25 |
Maximum Capacity (m³/h) | 16 | 25 | 40 |
T.D.R | 1 : 160 | ||
Error P Qmax - Qt | Within ±1.5 | ||
Error P Qt - Qmin | Within ±3.0 | ||
Using Gas | LPG, LPG, Inert Gas | ||
Body Material | Tinning and Aluminium Steel | ||
Pulser | Magnet for the pulse was installed inside. | ||
Approval | Korean Type Approval |
G1.6, G6
FEATURES
- Compact residential Diaphragm Gas Meter
- Long term accuracy and reliability
- Environment-friendly design
- Compliance with OIML and international standard
SPECIFICATIONS
Left/Right Scroll
CATEGORY | KG2 | KG3S | G1.6 | G2.5 | G4.0 | G6.0A | G6.0B | |
---|---|---|---|---|---|---|---|---|
Max Capacity (m³/h) | 2.5 | 2.5 | 4 | 6 | 10 | |||
Min Capacity (m³/h) | 0.016 | 0.016 | 0.025 | 0.04 | 0.06 | |||
Cyclic Volume (L/rev) | 0.4 | 0.78 | 1 | 1 | 1.2 | 2 | ||
Max Counter (m³/h) | 999.999 | 999.999 | ||||||
Max Operating pressure (kPa) | 50kpa | |||||||
Min Counter (L) | 0.2 | |||||||
Accuracy | Qmin≤Q<0.1Qmax | ±3.0 | ||||||
0.1Qmax≤Q≤Qmax | ±1.5 | |||||||
Temperature (°C) | -20 ±55 | |||||||
Weight (Kg) | 1.5 | 1.6 | 1.6 | 2 | 2.8 | 3.0 | ||
Connecting pipe (UNION) | 15mm PT1/2" | 15mm PT1/2" | 20mm PT3/4" | 20mm PT3/4" | 20mm PT3/4" | 25mm PT1" |